    1.General description This series vacuum contactor is suitable for power network of AC 50Hz,the main circuit rated voltage 1140V,rated current is 1000A-1250A,for making,breaking,frequently starting and controlling AC motor,and suitable for forming magnetic starter with a variety of protectors(JDB......

    Send Inquiry

    Product Description

    1.General description
        
    This series vacuum contactor is suitable for power network of AC 50Hz,the main circuit rated voltage 1140V,rated current is 1000A-1250A,
    for making,breaking,frequently starting and controlling AC motor,and suitable for forming magnetic starter with a variety of protectors
    (JDB electronic integrated protection,JR9 type over current protection devices,the RC absorption device),especially suitable for components
    widely used anti-explosion magnetic starter and large mineral lapping switch equipment.
        The contactor complies with GB/T 14048.4,IEC 60947-4-1 and JB/T 7122 standard,the main performance indicators have reached the international level.

    2. Normal using conditions
    a. Environment temperature : -5ºC~+40ºC, and average value is no more than +35ºC within 24 hour.
    b. Altitude: no more than 1000m.
    c. Atmospheric conditions: monthly highest humidity in the most wet month is no more than 90% and monthly average minimum temperature 
    shall be 25ºC. Condensation on the products due to temperature changes shall be considered.
    d. Impact vibration: The place is without extensive shaking, impact, and vibration.
    e. The place is without explosion hazard, enchant gas and sleet.
    f. No rain and snow in places
    g. Pollution degree: Three grade
    h. Installation type: .III
    i. Installation condition: Slant angle between installation surface and vertical surface is no more than 15°.
    3.Main technical parameter
    ItemUnitCKJ-5-1000~1250/1.14
    Main circuit rated voltagekV1.14
    Main circuit rated currentA10001250
    Main circuit making capacityA/100times6000
    Main circuit breaking capacityA/100times4500
    Limit breaking capacityA/3times5000
    Electrical life AC3times600,000
    Electrical life AC4times60,000
    Mechanical life timetimes1,000,000
    Rated operating frequency AC3times/h600
    Rated operating frequency AC4times/h120
    Short-time operating frequency(20s)times/h1000
    Clearance between open contactsmm2.8±0.1
    Over travelmm1.0±0.1
    4.International fairs1.14kv 1000A 1250A Low Voltage Vacuum Contactor for Mining (CKJ5)
    5. Company show
    1.14kv 1000A 1250A Low Voltage Vacuum Contactor for Mining (CKJ5)1.14kv 1000A 1250A Low Voltage Vacuum Contactor for Mining (CKJ5)1.14kv 1000A 1250A Low Voltage Vacuum Contactor for Mining (CKJ5)1.14kv 1000A 1250A Low Voltage Vacuum Contactor for Mining (CKJ5)
    1.14kv 1000A 1250A Low Voltage Vacuum Contactor for Mining (CKJ5)

    Related Category

    Send Inquiry

    Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
    Click Refresh verification code

    Leave Your Message

    • Click Refresh verification code